current position:home > machine equipment >

easy to operate waste stator rotor generator for coppe

stator and rotor generators

Alibaba.com offers 3,463 stator and rotor generators products. About 26% of these are other motor parts, 1% are pumps, and 1% are construction machinery parts. A wide variety of stator and rotor generators options are available to you, such as screw pump, piston pump.

100% copper rotor alternator

Alibaba.com offers 71 100% copper rotor alternator products. About 76% of these are alternative energy generators, 7% are diesel generators, and 1% are car alternator. A wide variety of 100% copper rotor alternator options are available to you, such as paid samples.

Environment: Wind Energy BasicsCopper

The primary use of copper in wind energy technologies is in the coil windings in the stator and rotor portions of the generator, in the high-voltage power cable conductors, and in the transformer coils. Copper is vital to the electrical grounding system for wind turbine farms.

Axial Flux, Modular, Permanent-Magnet Generator with a

The stator and rotor cores can be made on a per pole basis, reducing the cost of complete dies required to stamp a conventional lamination configuration. The geometry of the stator and the rotor core could have been optimized, however, this project focuses on the proof of concept. A. Rotor The cross section of the stator and rotor pole is .

Electric generatorStator windings | B

Electric generator - Stator windings: The maximum value of flux density in the air gap is limited by magnetic saturation in the stator and rotor iron, and is typically about one tesla (weber per square metre). The effective, or root-mean-square (rms), voltage induced in one turn of a stator coil in a 2-pole, 60-hertz generator is about 170 volts for each metre squared of area encompassed by .

What is rotor in a generator

A rotor is the rotating part of the inner segment of a generator that sets up the flux linkage in the stator winding.

Hydro Generator Maintenance Testing Discussion

Hydro Generator Maintenance Testing Discussion W. Howard Moudy Director of Service Management National Electric Coil [email protected] 724-787-4967 www.National-Electric-Coil.com 2013 Northwest Hydroelectric Association Hood River, OR May 23 & 24, 2013

Generator CoolersUnifin

from the stator and rotor pass through the coolers, transferring heat to the fins and cooler tubes. Known for their unmatched reliability, Unifin’s generator coolers are designed and built to provide efficient power generation over the long haul. Designed and Built for High Performance Stator Water Coolers When Gas Cooling Alone is Not Enough

Rotor Testing With MCEPdMA

rotor slots then shorted together at either end of the rotor using copper or aluminum “shorting” rings. Shorting rings are commonly referred to as end rings. The rotor bars are welded, brazed, or bolted to the end rings. If it is a cast aluminum rotor the shorting ring and the rotor bars are cast at the same time and no connecting joints exist.

Field coilWikipedia

The field coils may be on the stator or on the rotor. The magnetic path is characterized by poles, locations at equal angles around the rotor at which the magnetic field lines pass from stator to rotor or vice versa. The stator (and rotor) are classified by the number of poles they have. Most arrangements use one field coil per pole.

What is rotor in a generator

A rotor is the rotating part of the inner segment of a generator that sets up the flux linkage in the stator winding.

Field coilWikipedia

The field coils may be on the stator or on the rotor. The magnetic path is characterized by poles, locations at equal angles around the rotor at which the magnetic field lines pass from stator to rotor or vice versa. The stator (and rotor) are classified by the number of poles they have. Most arrangements use one field coil per pole.

SGen-3000W water- cooled generator series

1 Stator: Fleet-proven design of water-cooled stator bars with hollow stainless steel conductors 2 Rotor: 10,000 start/stop cycles without rotor removal during operational life cycle 3 Generator frame with integral coolers: easy service and maintenance of axial coolers 4 Shaft sealing: low maintenance gland seals with operational track record

Axial-Flux Motors and Generators Shrink Size, Weight

Manufacturing: AF machines have thus far been very difficult to manufacture because the stator iron’s design has continued to be based on that of an RF machine, using a stator yoke to close the flux loop. Magnetic forces between the rotor and stator discs tend to make it very difficult to keep the air gap between them uniform.

(PDF) Behaviour of Copper in Generator Stator Cooling

Behaviour of Copper in Generator Stator Cooling-Water Systems . of any damage to the copper strands in the stator winding. . In generators with high output stator and rotor windings have been .

Aluminum windings for generatorsElectric power

 · For example, a generator with 5 lbs of copper windings can use aluminum instead for a $17/unit cost save. It seems that whatever special terminal ends or manufacturing considerations are necessary to make this work would be well worth it.

Axial-Flux Motors and Generators Shrink Size, Weight

Today, most electric machines operate with radial flux (RF). Magnax offers a new concept, though—a machine that operates with axial flux (AF). The yokeless, permanent-magnet topology offers greater efficiency around the motor’s central axis, and wastes very little copper on windings.

Electrical 11 Flashcards | Quizlet

Electrical 11. STUDY. PLAY. T/F The synchronous motor is an induction motor. . The output frequency of an alternator is controlled by the. number of stator poles and rotor rotation speed. The non-rotating part of an alternator is called the. stator. Split-phase motors are so named because they operate on single-phase voltage, ut internally .

Unit 31- DC Motors Flashcards | Quizlet

-The armature or rotor (rotating member) contains permanent magnets.-The rotor is surrounded by fixed stator windings.-The stationary armature or stator winding is generally three phase, but some motors are designed to operate on four-phase or two-phase power. -Two-phase stator windings are commonly used for motors intended to operate small fans.

A New Generation of Axial Flux EV Motors | Design News

 · To produce rotation in a synchronous BLDC motor, windings of copper wire—called the stator—surround the rotor and interact with the magnetic fields of the permanent magnets. By carefully energizing different regions of the stator at exactly the right time, a rotational force can be imparted to the rotor and the motor spins.

Vertical Wind turbine and 3Phase alternator 9 Coils / 12

 · Vertical Wind turbine and 3Phase alternator 9 Coils / 12 magnets by iZe is licensed . that design is beautiful and effective but is missing of a home makeable generator. . After a field test on the alternator the result was not satisfying and I choose to redesign the whole stator and rotor to fit bigger coils 5 times more copper than the .

Troubleshooting for Generator No Electricity Output

 · Fault diagnosis and troubleshooting method. Generator overheating (1) The generator does not operate in accordance with the specified technical conditions, such as too high stator voltage, iron loss increases; if the load current is too large, the copper loss of the stator winding increases; if the frequency is too low, the cooling fan speed becomes slow, affecting the heat dissipation of .

Why Armature Winding on Stator in Synchronous Machine

 · It is more economical to provide Armature winding on Stator and Field winding on rotor. Let us consider a three phase Star connected 750 MVA, 21 kV Synchronous Machine. Line Current = (750×10 3)/(1.732×21) = 20,620 A. If the armature winding is placed on the Rotor, we need three slip rings each capable of handling 20,620 A.

EnergiTree | P

The EnergiTree is perfectly suited for remote locations, farms, disaster relief, and military expeditionary use. It uses Primo’s innovative and patented torque based blade and rotor design that provides real usable power in the common wind speeds of 5-15 mph and has already been proven in …